MANAGEMENT SYSTEMS
Documented quality, environmental and occupational safety management, plus TSE-verified fire performance. All certificates are available below as PDF.
In Composites, Quality Is Invisible
A composite part is manufactured together with its material. Resin ratio, fibre orientation, void content and degree of cure are all set during production — and none can be judged by looking at the finished part. A laminate that looks flawless may contain 5% voids.
That is why a certificate is not wall decoration for us; it is the mechanism that guarantees the invisible. Our management system certificates prove the consistency of the process , while our TSE fire reports prove the performance of the product . Neither means much without the other.
Why ISO Matters in Composites
ISO CERTIFICATES
Our integrated management system is certified by QA Technic International.

Planning, monitoring and continual improvement of processes. In composite manufacturing this secures recipe control, raw material traceability and the recording of process parameters.
Valid until: 08.06.2027

Styrene (VOC) emissions, waste management, dust control and scrap reduction. The move to closed-mould processes is this system's most tangible output.
Valid until: 08.06.2027

Chemical exposure, peroxide safety, fire risk and ergonomics. An occupational safety system built around the specific risk profile of a composite workshop.
Valid until: 08.06.2027
QA Technic International is accredited by IAS under MSCB-208 . IAS is a signatory to the Global Accreditation Cooperation (Global ACI) Multilateral Recognition Arrangement (MRA). The certificates were issued on 09.06.2026 and are subject to annual surveillance audits.
FIRE AND APPROVALS
Our rail laminate was tested at the TSE Construction Materials Fire and Acoustics Laboratory.
Our painted glass fibre reinforced laminate meets, in requirement set R1 of TS EN 45545-2:2023, the limit values of all three hazard levels — HL1, HL2 and HL3. HL3 is the highest fire requirement level, covering underground metro systems and long tunnels; a material meeting HL3 may be used in every lower-level application as well.
Measured Values
| Parameter | Test method | Measured | HL3 limit | Result |
|---|---|---|---|---|
| MARHE (kW/m²) | TS ISO 5660-1 | 59,73 | ≤ 60 | R1; HL1, HL2, HL3 |
| Ds(4) | TS EN ISO 5659-2 | 101,13 | ≤ 150 | R1; HL1, HL2, HL3 |
| CITG | TS EN 45545-2 Annex C | 0,68 | ≤ 0,75 | R1; HL1, HL2, HL3 |
Laminate Tested
| Product | Painted fibreglass part — for use in rail vehicles |
|---|---|
| Thickness | ~3.12 mm |
| Mass per unit area | 4.88 kg/m² |
| Gelcoat | Büfa Firestop GC S285-SV GRAY — 0.8 kg/m² |
| Resin + reinforcement | Büfa Firestop 8175-W-1 + Şişecam glass fibre — 1.1 kg polyester + 0.6 kg fibre / m² |
| Primer | Teknomarin acrylic-polyurethane flame retardant, RAL 7035 grey matt — 50-60 µm |
| Top coat | Teknomarin acrylic-polyurethane, RAL 9001 — 50-60 µm |
Download the Reports
- Report 304218 — Reaction to Fire Classification Report TS EN 45545-2 : 2023 · Requirement set R1 — all of HL1, HL2 and HL3 PDF
- Report 304180 — Rate of Heat Release — Cone Calorimeter Test TS ISO 5660-1 : 2015 · MARHE 59.73 kW/m² (HL3 limit ≤ 60) PDF
- Report 304158 — Smoke Generation — Optical Density Test TS EN ISO 5659-2 : 2018 · Ds(4) 101.13 (HL3 limit ≤ 150) · CITG 0.68 (HL3 limit ≤ 0.75) PDF
- Report 304143 — Flame Spread — Lateral Spread, Vertical Configuration TS EN ISO 5658-2 : 2015 · Lateral flame spread test for building and transport products PDF
Testing was carried out at the TSE Test and Calibration Centre, Construction Materials Fire and Acoustics Laboratory. The laboratory is accredited by TÜRKAK under AB-0001-T to TS EN ISO/IEC 17025:2017. TÜRKAK is a signatory to the European co-operation for Accreditation (EA) Multilateral Agreement and to the ILAC Mutual Recognition Arrangement. Reports are electronically signed; copies without signature and QR code are not valid. A test report does not replace a "Product Certificate".
FREQUENTLY ASKED QUESTIONS
ISO 9001:2015 Quality Management System (QA/TR/9001/2224), ISO 14001:2015 Environmental Management System (QA/TR/14001/1697) and ISO 45001:2018 Occupational Health and Safety Management System (QA/TR/45001/1189). All three were issued by QA Technic International and are valid until 08.06.2027.
According to TSE classification report no. 304218, our painted glass fibre reinforced laminate meets requirement set R1 at hazard levels HL1, HL2 and HL3 of TS EN 45545-2:2023. HL3 is the highest requirement level, covering underground metro systems.
The reports are electronically signed by TSE and carry a QR code on every page. They can be verified through TSE''s verification address using the report code. Copies without signature and QR code are not valid.
The ISO certificates were issued by QA Technic International, accredited by IAS under MSCB-208; IAS is a signatory to the Global Accreditation Cooperation (Global ACI) MRA. The fire tests were performed at the TSE Construction Materials Fire and Acoustics Laboratory'; the laboratory is accredited by TÜRKAK under AB-0001-T to TS EN ISO/IEC 17025:2017.
NEED ORIGINAL COPIES OF OUR CERTIFICATES?
We can send signed copies of all certificates and reports for your tender file.
Contact Us